Power on, the screen displays as shown in the figure.

Figure 4-1
Press the |Execute| key, and the screen enters the mode selection menu, as shown in the figure.

Figure 4-2
4.1. Dynamic Balancing Tester Speed Measurement:
When only speed measurement is performed, simply connect the Hall sensor to the instrument, and place a small magnet on the surface of the rotating pulley. After power-on, in the mode selection menu (Figure 4-2), select

Figure 4-3
4.2. Dynamic Balancing Tester Vibration Intensity Measurement:
When only vibration intensity measurement is performed, simply connect the velocity sensor to the vibration input jack on the instrument panel, and fix the velocity sensor to the measurement point. In the mode selection menu (Figure 4-2), move the cursor to

Figure 4-4
Where
×1: Magnification factor, used to improve the reading resolution of the vibration value A. Press the ▲ or ▼ key to switch between “×0.1, ×1, ×10, ×100”.
Channel label: Press the |◄| key to switch between channel A and channel B.
Press the |+| key to switch the measurement value between vibration severity (mm/s) and displacement peak-to-peak (um).
Generally, at low speeds below 10,000 rpm, displacement peak-to-peak (um) measurement is selected. It is suitable for most users. The following examples use the displacement setting.
4.3. Dynamic Balancing Tester Field Balancing
4.3.1. Symbol Definitions
● Single Plane
A0: Original vibration;
A01: Vibration after trial weight;
P: Trial weight;
K: Influence coefficient;
M: Balance weight.
● Two Planes
i: Measurement point number;
j: Balancing weight plane number;
A(1,0)、B(2,0): Original vibration of measurement points A and B;