Debugging Complete Comprehensive Test Bench Switchgear Power-on Test Bench



Debugging Complete Comprehensive Test Bench Switchgear Power-on Test Bench Product Features:

 



1. Can accurately measure the capacity of various transformers, convenient and accurate;



2. Can measure no-load current, no-load loss, short-circuit voltage, short-circuit loss, and zero-sequence impedance of various types of transformers;



3. Can automatically perform waveform distortion correction, temperature correction, voltage correction, and current correction. The operator only needs to input the correction index according to the transformer type, and the instrument can automatically calculate the corrected result. It is very suitable for units that do not have conditions for short-circuit tests on slightly larger capacity transformers;



4. Allows external connection of voltage transformers and current transformers for range expansion measurement, and can measure test objects with any parameters;



5. Wide voltage range: maximum voltage measurement up to 750V, accuracy guaranteed without switching gears. It will not damage the instrument due to incorrect voltage gear selection;



6. Large screen, high-brightness LCD display, full Chinese menu and operation prompts to achieve friendly human-machine dialogue, buttons make operation easier, wide-temperature LCD with brightness adjustment, adaptable to winter and summer seasons;



7. Users can print out the test data at any time through the micro printer.

 



Debugging Complete Comprehensive Test Bench Switchgear Power-on Test Bench Main Performance



Adopts three-phase four-wire input mode, AC380V input;

Three-phase voltage AC380V fixed voltage output one group (current less than or equal to 10A)

Three-phase voltage AC0-430V adjustable output one group (current less than or equal to 10A)

Three-phase current AC0-10A adjustable output one group (voltage less than or equal to 10V)

Three-phase current AC0-10A adjustable output one group, independent voltage regulation output, with capacitor input and exit; reactor input and exit functions (used to verify reactive power compensation characteristics of capacitor cabinets)

Phase sequence detection function: 0-480V voltage, can judge positive phase sequence, reverse phase sequence;

Electric stopwatch timing function: starts timing after collecting the capacitor cabinet switch signal, stops timing after the switch signal disappears;

All display instruments use national standard universal 44L1 pointer meters, easy for inspection and replacement, accuracy class 1.5;

Equipped with 3-inch universal wheels for easy movement;

DC fixed voltage 12V, 24V, 36V, 110V, 220V, current less than or equal to 20A.

The input circuit is equipped with an air switch, and the output circuit is equipped with a fuse. Overcurrent will not damage the instrument.



Technical Parameters:

Input Power: Three-phase four-wire AC380V

Output Voltage and Current:

1. Three-phase AC 0 – 10A output (<100V, adjustable value> one group

2. Three-phase AC100V output (fixed value) one group

3. AC operation voltage output AC 0~400V, at 220V, current less than 10A

4. DC operation voltage output DC 0~260V

5 Single-phase AC220V output (fixed value, socket form) two groups,

6 Three-phase AC380V output (fixed value, terminal) one group,

Usage Instructions:

1. Connect three-phase four-wire AC380V

2. Connect the output DC300V to the load

3. Turn the output adjustment knob counterclockwise to zero.

4. Check and confirm the wiring is correct

5. Close the power switch

6. Slowly adjust the output adjustment knob to raise the voltage to an appropriate value.

7. After the test is completed, first turn the output adjustment knob counterclockwise to zero, then disconnect the power switch. After discharge is complete, you can start disconnecting the wires.